logo
language iconarrow
menu icon

ISO 45001

45001-17 Annex A as an aid to application

4 min read · IA, EA

All articles

For: IA, EA
Source: DIN EN ISO 45001:2023-12, German, text version ISO 45001:2018. Annex A, the heading “informative”, in particular A.1, A.2 and A.3. English for cross-checking. National footnotes of the DIN edition, where they occur in the articles.

The heading reads “Annex A (informative) — Guidance on the use of this document”. A.1 says that the explanatory information is intended to prevent misinterpretation. It deals with the requirements and is consistent with them. It is not intended to add to them, to diminish them, or to change them in any way.

The next sentence of A.1 says, in the German, that the requirements should not be viewed in isolation, but need to be viewed from a system perspective, because there could be interrelationships between clauses. The English text says “need to be viewed from a systems perspective and should not be taken in isolation”. That is the reading key of the Annex, not an additional “shall” alongside clauses 4 to 10.

The same shift occurs at further places in the German Annex. A.5.3 says “muss” of the point that every person in the workplace also takes account of the safety and health of others. The English text says “needs to take account”. A.8.1.1 says “müssen” of operational planning and of reduction to a level as low as reasonably practicable. The English text says “need to” and “as low as reasonably practicable”. A.8.1.4.3 says “muss” of retaining control when outsourcing. The English text says “needs to have control”. A.9.3 says that the topics of the management review need not all be addressed at the same time. The English text says “need not”. In each of these cases, A.1 remains decisive. The auditable requirement stands in the relevant clause of 4 to 10, not in the Annex. The articles 45001-03, 45001-09, 45001-12 and 45001-15 name the place in question.

A.2 repeats that there are no normative references. Users can draw on the bibliography. The documents named there, from ISO 9000:2015 through ISO 19011, ISO 31000, IEC 31010, ISO 37500 and ISO 39001 to the ILO publications and OHSAS 18001 and OHSAS 18002, are not retold here. A reference remains a reference.

A.3 gives selected explanations of words, so that misunderstandings are avoided. That is guidance, and according to A.1 it does not change the requirements. For reading the “muss” sentences it still matters, because the same words stand in the requirements.

a) “Fortlaufend” denotes a duration over a period of time, with interruptions. “Stetig” denotes a duration without interruption. For improvement, “fortlaufend” is the word. That applies to 3.37, Note 2.

b) “Berücksichtigen” means thinking something through that can be excluded. “Rechnung tragen” means thinking something through that cannot be excluded. The English text uses “consider” and “take into account” for these.

c) “Angemessen” means suitable and includes a degree of freedom. “Geltend”, “anwendbar”, “zutreffend” and “geeignet” are not the same word. They mean that the application is relevant or possible, and they imply that it shall be done if it can be done. The words are not interchangeable.

d) “Interessierte Partei” and “Anspruchsgruppe” name the same term.

e) “Sicherstellen” means that responsibility can be delegated, but not the accountability for ensuring that the performance is secured.

f) “Dokumentierte Information” covers documents and records. “Aufbewahren dokumentierter Information als Nachweis” refers to records. “Als dokumentierte Information aufrechterhalten” refers to documents, including procedures. The formulation as evidence is not intended as a requirement that the retained information satisfy legal certainty. It determines the kind of record. Where a clause requires both, “aufrechterhalten und aufbewahren”, the article names both verbs and does not collapse them into one.

g) Activities “im Einflussbereich der Organisation” are those in which the organization, in line with its legal requirements and other requirements regarding OH&S performance, has a share in the control of the means or methods, or in the direction of the work.

A.3 also says: if the organization is subject to requirements that prescribe other terms and meanings, and it uses them, conformity with this document remains required.

The national footnotes N1 to 8.1.2 and N2 to A.7.2 are footnotes of the DIN edition. N1 refers to § 4 of the Occupational Health and Safety Act and to the STOP principle. N2 explains “Rolle”. Neither is a requirement of ISO 45001:2018. N1 is named in 45001-10 only as a footnote, without explaining the statute.

The example catalogues in A.4 to A.10 show what a process can include, or what an organization should consider. Where the guidance says that a list in 6.1.2.1 is not exhaustive, or that its own letters do not correspond to the list of requirements, that is a note on how to read it and not permission to shorten the “muss” sentences. An auditor who treats a “sollte” list in the Annex as a missing requirement goes beyond A.1.

Not in this text: an audit checklist drawn from Annex A, a second list of requirements, and the content of the documents in the bibliography. Figure 1 and the index are not taken over. An amendment on climate change is not contained in this PDF.