45001-14 Monitoring and evaluation of compliance

3 min read · V, IA

All articles

For: V, IA
Source: DIN EN ISO 45001:2023-12, German, text version ISO 45001:2018. 9.1.1, 9.1.2. Annex A.9.1 as guidance. English for cross-checking.

9.1.1 and 9.1.2 are two processes.

9.1.1 requires processes for monitoring, measurement, analysis and performance evaluation. The organization shall determine:

a) what shall be monitored and measured, including the extent to which legal requirements and other requirements are fulfilled; the activities and operations related to identified hazards, risks and opportunities; progress towards the OH&S objectives; the effectiveness of operational and other controls;

b) the methods, as applicable, in order to ensure valid results;

c) the criteria against which it evaluates its OH&S performance;

d) when monitoring and measurement are carried out;

e) when the results are to be analysed, evaluated and communicated.

It shall evaluate OH&S performance and determine the effectiveness of the system. Monitoring and measuring equipment shall, as appropriate, be calibrated or verified and used and maintained in a suitable manner. The note says that there could be legal requirements and other requirements concerning calibration or verification, for example national or international standards. “Können”. 9.1.1 does not prescribe traceability to a measurement standard of the kind in ISO 9001.

9.1.2 is called “Bewertung der Compliance” in the German version. The organization shall establish, implement and maintain processes in order to evaluate compliance with the legal requirements and other requirements from 6.1.3. It shall determine the frequency and the methods, evaluate compliance and, if necessary, take action, with a reference to 10.2, maintain knowledge and understanding of its compliance status, and retain documented information on the results.

That 9.1.1 also names, among what shall be monitored and measured, the extent to which legal requirements and other requirements are fulfilled does not set 9.1.2 aside. 9.1.2 is the evaluation process of its own, with frequency, method, knowledge of status, and action if necessary.

A.9.1.1, guidance, gives examples of what can be monitored and measured: complaints, the health of workers through medical examinations, the work environment, incidents, the effectiveness of controls and of emergency exercises, and competence. Further examples concern the fulfilment of legal requirements, including the status of gaps that have been identified, and the fulfilment of other requirements, including collective agreements that are not legally binding, standards, the organization’s own rules and terms of insurance. Criteria can serve for comparison. Indicators can be the frequency, nature, severity or number of incidents, or a proportion of corrective actions completed on time. The guidance describes monitoring, measurement, analysis and performance evaluation in separate sentences. Performance evaluation is said to be the activity by which suitability, adequacy and effectiveness are determined in order to achieve the objectives that have been set. The examples and the possible indicators are not copied out as a required catalogue. A percentage there is an example, where the criterion is a comparison of completed corrective actions, not a specification of this standard.

A.9.1.2, guidance: frequency and timing can vary according to the importance of the requirement, changes in operating conditions, changes in legal requirements and other requirements, and performance to date. An organization can use various methods in order to maintain knowledge and understanding of its compliance status. A.9.1.2 of this document does not contain a sentence on whether a non-compliance is at the same time a nonconformity. If a nonconformity is present, 10.2 applies. Where action is necessary, 9.1.2 requires it, with a reference to 10.2.

Documented information: 9.1.1 requires appropriate documented information to be retained as evidence of the results of monitoring, measurement, analysis and performance evaluation, and of the maintenance, calibration or verification of measuring equipment. 9.1.2 requires documented information on the results of the compliance evaluation to be retained.

Not in this text: a system of indicators, a calibration interval, a legal register, and the statement that, under this document, every non-compliance is automatically a nonconformity. The PDF does not make that statement in A.9.1.2. The two processes remain 9.1.1 and 9.1.2.